PROTEK AQUADEM PRODUCKT
 
AQUADEM
AQUADEM REVERSE OSMOSbrosür brosür
   

Reverse Osmasis System
Reverse osmosis is the passage of a low concentration compound in a liquid from a semi-permeable tissue through a high concentration of liquid by applying pressure to the liquid. Operation in the reverse osmosis device: the water to be treated by means of the high pressure pump is supplied to the membranes at high pressure to allow the passage of water molecules to the product part of the membraner. 

altThe water to be treated in the Double Pass RO device is obtained by passing through the membrane filtration in series at 2 stages. This can be done with 2 different RO devices or 2 steps on a single device. The device is running ONLINE and is supplied for the use of hemodialysis devices without stored purified water and with the lowest possible contact surface.

 

Advantages of the Double Pass Online Reverse Osmasis System
  • Operating costs are very low.
  • It provides very high quality water with lower conductivity for dialysis treatment.
  • The product in the RO membranes is not affected by the increase in the conductivity of the product at low amounts. When the device is running ONLINE and contamination from the storage system is eliminated, bacteria and endotoxin are not seen in the system.
  • RO Device can be designed as PLC (Programmable Logic Control System) controlled or standard as requested.

 

TECHNICAL SPECIFICATIONS OF AQUADEM ULTRA DOUBLE PASS RO DEVİCE
  • Design for capacity increase
  • Membrane inlet and outlet pressure manometers – separately for both units
  • Front filter inlet and outlet pressure manometers –bar
  • Line feed and return manometers - bar
  • Product water, Waste water, Circulating water flow meters - Liter / minute Warning lights
  • Low Pressure automatic safety lock

On PLC controlled devices
  • 5.6 "color LCD display
  • From the status page; System status, Storage full / empty, Pressure status, Conductivity status
  • Automatic and Manual Rinse (Flush)
  • Adjustable alarm limit values Water from the "WATER QUALITY" page: Input Water
  • Conductivity - µS / cm Product Water Conductivity - µS / cm Input Water Temperature - ºC Rejection -% Pump Run Time - hours
  • RS 232
  • Fault indicator table Warnings and alarms
  • PRODUCT WATER HIGH CONDUCTIVITY,INTRODUCTION WATER HIGH CONDUCTIVITY,INTRODUCTION LOW LOW PRESSURE,LINE HIGH PRESSURE
  • Dialysis centers produce water in accordance with European Pharmacopoeia standards, which are pure water criteria.

    MEMBRANE DIVISION PRODUCT WATER
    L / Saat
    DIMENSIONS (mm) (mm) G / Y / D OPERATING VOLTAGE
    RO 1 RO 2 RO 1 RO 2
    4 4 1256 1256 2400 x 1570 x 800 380 VAC / 50 Hz / 14 A
    6 6 1884 1884 2400 x 1570 x 800 380 VAC / 50 Hz / 14 A
    8 8 2512 2512 2400 x 1570 x 950 380 VAC / 50 Hz / 14 A
    10 10 3140 3140 2400 x 1570 x 950 380 VAC / 50 Hz / 14 A
    12 12 3768 3768 2400 x 1570 x 950 380 VAC / 50 Hz / 14 A

  • Product water capacity is given according to 25 °C inlet temperature.
  • Different numbers of membranes can be found in the RO1 and RO2 units according to the requested capacity.
  • The device is CE certified according to the Medical Device Directive 93/42 EEC II B.

 
Dogu Sanayi Sitesi 13. Blok No: 7/A Yenibosna / Istanbul- TURKEY
Tel: +09 0212 551 24 74 Fax: +09 0212 551 78 33 E-mail: sales@protekteknik.com.tr